uv 01 kUV-01


UV-01


UV-01.LU


UV flame detector
The UV flame detector is especially well suited for the detection of open flames and arcs, the detector is not sensitive to sparks, most artificial light sources, daylight and direct sunlight.

Operating voltage/current: 15 … 30VDC/100µA
Alarm resistor: 560Ω (Standard)
System: Two-wire operationProtection class: IP65
Housing dimensions: Ø: 40mm, L: 77mm (without ventilation)
Housing dimensions: Ø: 40mm, L: 95mm (with ventilation)

uv 01 ex kUV-01.EX


UV-01.EX


UV flame detector ATEX 2GD
Like UV-01, with 10m cable (cast in housing)
Operating voltage/current: 15 … 30VDC/100µA
Alarm resistor: 560Ω (Standard)
System: Two-wire operation
Housing dimensions: Ø: 42mm, L: 127mm

uv 02 oB k
UV-02


UV-02


UV flame detector

The UV flame detector is especially well suited for the detection of open flames and arcs, the detector is not sensitive to sparks, most artificial light sources, daylight and direct sunlight, potential-free changeover for malfunction and alarm, various configuration options via DIP switches.

Operating voltage/current: 18 … 30VDC/400µA
Alarm resistor: 560Ω (Standard)
System: Two, three and four wire operationProtection class: IP65
Housing dimensions: 125x80x57mm

uv 03 oB kUV-03 without air purge

uv 03 kUV-03.LU with air purge


UV-03






UV-03.LU


UV flame detector

The UV flame detector is especially well suited for the detection of open flames and arcs, the detector is not sensitive to sparks, most artificial light sources, daylight and direct sunlight, various configuration options via DIP switches.

Operating voltage/current: 15 … 30VDC/100µA
Alarm resistor: 560Ω (Standard)
System: Two-wire operation
Protection class: IP65
Housing dimensions: 98x64x35mm

 

UV 03 ABS kUV-03.ABS


UV-03.ABS


UV flame detector
The UV flame detector is especially well suited for the detection of open flames and arcs, the detector is not sensitive to sparks, most artificial light sources, daylight and direct sunlight, the detector is especially suitable for use in aggressive environments, as for example on exhaust hoods in labs due to the plastic housing, various configuration options via DIP switches.

Operating voltage/current: 15 … 30VDC/100µA
Alarm resistor: 560Ω (Standard)
System: Two-wire operation
Protection class: IP65
Housing dimensions: 90x120x50mm

UV 03 A kUV-03.A


UV-03.A


UV flame detector

The UV flame detector is especially well suited for the detection of open flames and arcs, the detector is not sensitive to sparks, most artificial light sources, daylight and direct sunlight, especially suited for extremely harsh industrial environments and tight spaces, various configuration options via DIP switches.

Operating voltage/current: 15 … 30VDC/100µA
Alarm resistor: 560Ω (Standard)
System: Two-wire operation
Protection class: IP65
Housing dimensions: 98x64x35mm
Pipe housing: 55x25x25mm